Click |
 |
to return to previous
page. |
|
|
|
Barber Jets and
Specifications |
| |
|
Barber Jets |
Model
Number |
Type
Jet |
Overall Length |
Approx. Weight |
Thread Size |
BTU/Hr |
Kcal/Hr |
Type
Gas |
|
in 1000's |
in 1000's |
|
in. |
mm |
oz. |
gm |
in. |
mm |
Min |
Max |
Min |
Max |
|
638 |
Impinged |
1 3/8 |
35 |
3/4 |
21 |
5/16 x 27 |
8 |
2.5 |
6.5 |
,625 |
1,625 |
City |
|
2.5 |
6.5 |
,625 |
1,625 |
LP |
|
640 |
Impinged |
1 1/2 |
38 |
7/8 |
25 |
5/16 x 28 |
8 |
5 |
10 |
1,25 |
2,5 |
City |
|
5 |
10 |
1,25 |
2,5 |
LP |
|
651 |
Slotted Cap |
2 1/8 |
54 |
1 1/4 |
35 |
*7/16 x 24 |
11 |
2.5 |
5 |
,625 |
1,25 |
City |
|
2.5 |
3.5 |
,625 |
,875 |
LP |
|
654 |
Slotted Cap |
2 3/16 |
55.5 |
2 1/8 |
60 |
*7/16 x 24 |
11 |
2.5 |
7.5 |
,625 |
1,875 |
City |
|
2.5 |
7.5 |
,625 |
1,875 |
LP |
|
668-S |
Pilot |
1 3/8 |
35 |
1 |
28 |
7/16 x 24 |
11 |
2.5 |
2.5 |
,625 |
,625 |
City |
|
2.5 |
2.5 |
,625 |
,625 |
LP |
|
642 |
Bell Baffle |
1 3/8 |
47 |
1 |
28 |
*7/16 x 24 |
11 |
1 |
3 |
,25 |
,75 |
City |
|
1 |
3 |
,25 |
,75 |
LP |
|
674 |
Flat Flame |
1 3/8 |
55.5 |
2 1/8 |
60 |
1/8" N.P.T. |
9,5 |
2.5 |
7.5 |
,625 |
1,875 |
City |
|
2.5 |
7.5 |
,625 |
1,875 |
LP |
|
670 |
Flat Flame |
1 3/8 |
39 |
1 |
28 |
1/8" N.P.T. |
9,5 |
1.5 |
3.5 |
,375 |
,875 |
City |
|
1.5 |
3.5 |
,375 |
,875 |
LP |
|
671 |
Slotted Cap |
1 3/8 |
39 |
1 |
28 |
1/8" N.P.T. |
9,5 |
1.5 |
3.5 |
,375 |
,875 |
City |
|
1.5 |
3.5 |
,375 |
,875 |
LP |
|
*Also available with 1/8" N.P.T.
Based on 3.5" w.c. for City gases and 11" w.c. gas pressure for LP
gases.
"City" gas is any gas with specific gravity of less
than 1.0; LP gas is any gas with a specific
gravity of more than 1.0 (Propane or Butane).
Flat flame jets have 1/8" N.P.T. so they are gas tight without
the hex bottoming. This allows turning of jets for exact
positioning of flat flame.
|
Impinged Jet Burner Unit Specifications |
Type
Jet |
BTU/Hr.
Per Jet |
Kcal/Hr.
Per Jet |
FLAME HEIGHT |
BTU/Hr. Per
Sq. Ft. of
Combustion
Area |
Kcal/Hr. Per
Sq. Meter of
Combustion
Area |
BTU/Hr. Per
Cu. Ft. of
Combustion
Area |
|
From Jet Tips |
From Bottom of Burner |
|
In Inches |
In mm |
In Inches |
In mm |
|
638 |
2,500 |
625 |
4 |
102 |
6 |
152 |
108,000 |
288,500 |
300,000 |
|
638 |
5,000 |
1,250 |
8 |
203 |
10 |
254 |
216,000 |
580,000 |
300,000 |
|
640 |
7,500 |
1,875 |
12 |
305 |
14 |
356 |
324,000 |
870,000 |
300,000 |
|
640 |
10,000 |
2,500 |
16 |
406 |
18 |
457 |
432,000 |
1,160,000 |
300,000 |
|
|
Slotted Cap and Flat Flame Burner Unit Specifications |
|
SLOTTED CAP and FLAT FLAME JET SPECS |
Type
Jet |
BTU/Hr.
Per Jet |
Kcal/Hr.
Per Jet |
FLAME DIMENSIONS |
|
Total Height |
Total Width |
|
In Inches |
In mm |
In Inches |
In mm |
|
651 |
2,500 to 5,000 |
625 to 1,250 |
1 1/2 to 2 1/2 |
38 to 63 |
1 to 2 |
25 to 51 |
|
654 |
7,500 |
1,875 |
3 |
76 |
3 |
76 |
|
|
654 jet is fired over 5,000 BTU/Hr and
up to 7,500 BTU/Hr, it must be spaced at. |
|